7 Troubleshooting
-
266
-
7.3 Description of Fault Levels
The NICE3000
new
has almost 70 pieces of alarm information and protective functions.
It monitors various input signals, running conditions and feedback signals. If a fault
occurs, the system implements the relevant protective function and displays the fault
code.
The controller is a complicated electronic control system and the displayed fault infor-
󶍾󶍽
are handled according to the following table.
󶙽Fault Levels
Fault Level Fault State Solution
Level 1
Display the fault code.
Output the fault relay action com-
mand.

󶍽
Level 2
Display the fault code.
Output the fault relay action com-
mand.
Continue normal running of the ele-
vator.

function is disabled.
-
ing function is disabled.
Level 3
Display the fault code.
Output the fault relay action com-
mand.
Stop output and apply the brake
immediately after stop.

elevator stops at special deceler-
ation rate, and cannot restart.

elevator does not stop. In nor-
mal-speed running, the elevator
stops, and then can start running
at low speed after a delay of 3s.
Level 4
Display the fault code.
Output the fault relay action com-
mand.
In distance control, the elevator
decelerates to stop and cannot run
again.

elevator stops at special deceler-
ation rate, and cannot restart.

elevator does not stop. In nor-
mal-speed running, the elevator
stops, and then can start running
at low speed after a delay of 3s.

elevator does not stop. In nor-
mal-speed running, the elevator
stops, and then can start running
at low speed after a delay of 3s.
Level 5
Display the fault code.
Output the fault relay action com-
mand.
The elevator stops immediately.

elevator stops immediately and
cannot restart.

elevator does not stop. In nor-
mal-speed running, the elevator
stops, and then can start running
at low speed after a delay of 3s.