7 Troubleshooting
-
281
-
Fault
Code
Name Possible Causes Solution Level
Err43
Up limit signal
abnormal.
Subcode 101: The up limit
switch acts when the elevator
is running in the up direction.
Check the signal feature (NO, NC) of the up
limit switch.
Check whether the up limit switch is in good
contact.
Check whether the limit switch is installed at
a relatively low position and acts even when
󶍿-
mally.
4A
Err44
Down limit
signal
abnormal.
Subcode 101: The down limit
switch acts when the elevator
is running in the down
direction.
Check the signal feature (NO, NC) of the
down limit switch.
Check whether the down limit switch is in
good contact.
Check whether the limit switch is installed at
a relatively high position and thus acts even
when the elevator arrives at the terminal
󶍿
4A
Err45
Slow-down
switch abnormal
Subcode 101: The down slow-
󶎀
during shaft auto-tuning.
Check whether the up slow-down and the
down slow-down are in good contact.
Check the signal feature (NO, NC) of the up
slow-down switch and the down slow-down
switch.
Ensure that the obtained slow-down dis-
󶍾
at the elevator speed.
4B
Subcode 102: The up slow-
󶎀
during shaft auto-tuning.
Subcode 103: The slow-down
switch is stuck or abnormal
during normal running.
Subcode 106: The up and
down slow-down switches 2
act improperly during shaft
auto-tuning.
Check whether the signal of the up and
down slow-down switches 2 is in wrong
sequence.
Check the signal feature (NO, NC) of the up
and down slow-down switches 2.
Subcode 107: The up and
down slow-down switches 3
act improperly during shaft
auto-tuning.
Check whether the signal of the up and
down slow-down switches 3 is in wrong
sequence.
Check the signal feature (NO, NC) of the up
and down slow-down switches 3.
Err46
Re-leveling
abnormal
Subcode 101: The leveling
signal is inactive during re-
leveling.
Check whether the leveling signal is normal.
2B
Subcode 102: The re-leveling
running speed exceeds 0.1 m/
s.
Check whether the encoder is used correctly