9 Description of Functions and Schemes
-
303
-
3 Parameters
Function
Code Name
Setting Range Default
F6-44
Fire
emergency
function
selection
state
Bit6: Closing door by holding down the door close button
Bit7: Reserved
Bit8: Door close at car call registering
Bit12: Not clearing car calls at reverse door open in
Bit14: Opening door by holding down the door open
button
16456
F5-a
Xa function
selection
11/43: Fire emergency signal NO/NC 0
F5-b
Xb function
selection
0
F5-c
Xc function
selection
0
F5-29
Y4 function
selection
0
F6-03
Fire
emergency
0 to F6-00 0
F8-12
Fire
emergency
0 to F6-00 0
■
Input setting
input via the MCB, perform parameter setting (takes input terminals Xa and Xb as an
example according to the preceding table.
The NICE3000
new
switch over signal is input via terminal X on the MCB (take input terminal Xc as an ex-
ample).
■
Output setting