Appendix B Parameter Table
-
354
-
Function
Code
Name Setting Range Default Unit Property Page
F6-28 󶍿 F6-01 to F6-00 1 -
P215
F6-29
Peak 2 start time for parallel/
group control
00.00 to 23.59 00.00 HH.MM
F6-30
Peak 2 end time for parallel/
group control
00.00 to 23.59 00.00 HH.MM
F6-31 󶍿 F6-01 to F6-00 1 -
F6-35 󶍿 0 to 65535 65535 -
P215
F6-36
󶍿
󶍿
0 to 65535 65535 -
P216
F6-37
󶍿
󶍿
0 to 65535 65535 -
F6-38 Elevator lock start time 00.00 to 23.59 00.00 HH.MM
F6-39 Elevator lock end time 00.00 to 23.59 00.00 HH.MM
F6-40 Program control selection 1
Bit0: Disability function
Bit1: Soft limit function
Bit2: JP16 input used as back door selection
Bit3: JP16 input used as the back door open
signal
Bit4: Opening only one door of opposite
doors under manual control
Bit5: Timed elevator lock
Bit6: Manual door
Bit7: Reserved
󶍿
󶍿
󶍾
Bit12: Car call assisted command in single
door used as disability function
Bit13: Folding command used as disability
function and back door function
Bit14: Car call command folding
Bit15: JP20 used for switchover to back door
(switch)
0 -
P216
to
P219
F6-41 Program control selection 2
Bit2: Inspection to stop due to slow-down
Bit4: Buzzer tweet during door open delay
Bit6: Canceling door open delay
Bit8: Elevator lock at door open
Bit9: Display available at elevator lock
Bit10: Elevator lock in the attendant state
Bit11: Blinking at arrival (within the time set
in F6-47)
Bit12: Door re-open during door open delay
Bit13: Door re-open after car call of the
󶍿
0 -
F6-42 Program control selection 3
Bit1: Canceling door open/close command
at delay after door open/close limit
Bit2: Not judging door lock state at door
close output
Bit3: Door close command output during
running
󶍿󶍾
󶍾
Bit5: Clearing calls immediately at elevator
lock
Bit6: Electric lock NC
Bit8: Canceling door open/close limit
detection
Bit9: Canceling scrolling display of faults
Bit10: Door open energy-saving
Bit11: Independent switch separated from
parallel connection
0 -