Appendix B Parameter Table
-
360
-
Function
Code
Name Setting Range Default Unit Property Page
Fd-07 HCB: JP1 input
0: Invalid
1: Elevator lock signal
2: Fire emergency signal
6 Door close button signal
1 -
★
P250
Fd-08 HCB: JP2 input 2 -
★
Fd-09 HCB: JP1 output
0: Invalid
1: Up arrival indicator
2: Down arrival indicator
3: Fault output
4: Non-door zone stop output
5: Non-service state output
6: Door close button indicator output
1 -
★
Fd-10 HCB: JP2 output 2 -
★
Fd-11 Expansion board 1: X1 input
0: Reserved
1: Fire emergency signal
2: Overload signal
3: Full-load signal
5: Door machine 1 light curtain signal
6: Door machine 2 light curtain signal
7: Brake travel switch feedback
8: UPS valid signal
9: Elevator lock signal
10: Safety circuit signal 2
11: Synchronous motor self-lock feedback
12: Door lock circuit 2 feedback
13: Door machine 1 safety edge signal
14: Door machine 2 safety edge signal
15: Motor overheat signal #
16: Earthquake signal
17: Back door forbidden #
18: Light-load signal #
19: Half-load signal #
22: Door 1 open
23: Door 2 open
24: Brake travel switch 2 feedback
25: External fault
27: Door 2 selection
28: Single/Double door selection NO input
NC point + 32
0 -
★
P251
Fd-12 Expansion board 1: X2 input 0 -
★
Fd-13 Expansion board 1: X3 input 0 -
★
Fd-14 Expansion board 1: X4 input 0 -
★
Fd-15 Expansion board 1: X5 input 0 -
★
Fd-16 Expansion board 1: X6 input 0 -
★
Fd-17 Expansion board 1: X7 input 0 -
★
Fd-18 Expansion board 1: X8 input 0 -
★
Fd-19 Expansion board 1: X9 input 0 -
★
Fd-20 Expansion board 1: X10 input 0 -
★
Fd-21 Expansion board 2: X1 input 0 -
★
Fd-22 Expansion board 2: X2 input 0 -
★
Fd-23 Expansion board 2: X3 input 0 -
★
Fd-24 Expansion board 2: X4 input 0 -
★
Fd-25 Expansion board 2: X5 input 0 -
★
Fd-26 Expansion board 2: X6 input 0 -
★
Fd-27 Expansion board 2: X7 input 0 -
★
Fd-28 Expansion board 2: X8 input 0 -
★
Fd-29 Expansion board 2: X9 input 0 -
★
Fd-30 Expansion board 2: X10 input 0 -
★