Introduction
-
6
-
Function Description Remarks
Down collective
selective control
In automatic running or attendant state, the elevator responds only to hall
down calls besides car calls.
-
Idle elevator
returning to
In automatic running state, the elevator automatically returns to the set
the set time.
F9-00 "Idle
time before
returning to
Landing at
If the door open time exceeds the door open protection time but the door
open limit signal is still inactive, the elevator closes the door and then
-
Forced door
close
When the door fails to close within the set time due to the action of the light
curtain or safety edge, the elevator enters the forced door close state, closes
the door slowly, and gives a prompt tone.
-
Cancellation of
wrong calls
Passengers can press the button consecutively twice to cancel wrong calls. -
setting
on actual requirements.
F6-05/06/35
Independent
running
The elevator does not respond to any call, and the door needs to be closed
manually. In the case of group control, the elevator runs independently out of
the group control system.
Signal input:
CCB JP23
Attendant
running
In attendant state, the running of the elevator is controlled by the attendant.
Signal input:
CCB JP21
Low-speed self-
rescue
When the elevator is in non-inspection state and stops at non-leveling area,
the elevator automatically runs to the leveling area at low speed if the safety
requirements are met, and then opens the door.
-
Door control
function
You can set whether the system keeps outputting commands after door open
limit and door close limit based on the type of the door machine.
-
Car arrival gong -
Hall arrival
forecast
indicator
forecast indicator becomes ON.
HCB product
output
Hall arrival gong
gong becomes ON.
HCB product
output
Hall I/O
extension
function
using MCTC-KZ-G1.
-
Car I/O
extension
function
using MCTC-KZ-G1.
-
Button stuck
check
The system can automatically identify whether a hall call button is stuck and
cancel the stuck call, preventing the condition that the elevator cannot close
and run due to stuck hall calls.
Bit4 of FE-32
Automatic
startup torque
compensation
The system automatically implements startup torque compensation based
on the current car load, achieving smooth startup and improving the riding
comfort.
F8-01 "Pre-
torque
selection"
Direct travel ride
The system automatically calculates and generates the running curves based
on the distance, enabling the elevator to directly stop at the leveling position
without creeping.
-
Automatic
generation of
optimum curve
The system automatically calculates the optimum speed curve compliant with
the human-machine function principle based on the distance, without being
-