Minimate Pro Operator Manual 41
4. UNIT LABEL INSTRUCTIONS
4.1. Condensed Instructions
Follow the Condensed Instructions, as shown below, and also displayed on the unit:
1. Connect the Geophone and/or Microphone sensors to the unit. Position the unit and sensor(s) at the
desired locations.
2. Turn the unit on by pressing On/Off (Refer to Note A).
3. Check the Battery Status and Memory availability screen. Charge or use the supplied adaptor, as
required.
4. When the Ready to Monitor screen appears, ensure that your sensor(s) are properly displayed
(Refer to Note B).
5. To verify or edit Setups, press Setup. For additional setup information, refer to the Minimate
Operator Manual.
6. Press Start Monitor to enter Monitoring Mode.
Note A:
If you have just received the unit, as a new product or from an Authorized Instantel Service and
Calibration Facility, you must connect the battery by plugging in the Instantel AC adapter and pressing
the On/Off key. You can also connect the battery by simultaneously holding down the Up Arrow and
Enter
keys for 3 seconds. While still holding down these keys, press the On/Off key.
Note B:
If you change your sensors, it is important to update the system after they are connected by pressing
Sensor Check.
IMPORTANT:
7. Store the unit on charge when not in use for optimum battery performance.
8. Refer to Section 7, Basic Tutorial, for step-by-step instructions to easily begin monitoring with your
Minimate Pro.
4.2. Battery, Shipping and Warranty Instructions
Prior to shipping the unit to an Authorized Instantel Service and Calibration Facility, the battery must
be disconnected by deactivating it through the Minimate Pro software interface. This is done
through a series of key presses, and does not require that the unit be opened. Follow the steps below:
1. Press Setup.
2. Select the Maintenance Menu.
3. Select Disconnect Battery by pressing the Right Arrow key; the battery disconnects and the
unit turns off.
WARNING: Only use the recommended Instantel AC Adapter to maintain optimum battery
performance. This product contains no user-serviceable parts. The Operator is NOT to replace the
battery. For additional information, refer to this manual.