Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS BIOS Setup Utility
Revision 1.8
Intel order number E39529-013
95
Main Advanced Security Server Management Boot Options Boot Manager
Assert NMI on SERR
Enabled/Disabled
Assert NMI on PERR
Enabled/Disabled
Resume on AC Power Loss
Stay Off/Last state/Reset
Clear System Event Log
Enabled/Disabled
FRB-2 Enable
Enabled/Disabled
O/S Boot Watchdog Timer
Enabled/Disabled
O/S Boot Watchdog Timer Policy
Power off/Reset
O/S Boot Watchdog Timer Timeout
5 minutes/10 minutes/15 minutes/20 minutes
ACPI 1.0 Support
Enabled/Disabled
Plug & Play BMC Detection
Enabled/Disabled
Console Redirection
System Information
Figure 39. Setup Utility — Server Management Configuration Screen Display
Table 32. Setup Utility — Server Management Configuration Screen Fields
Setup Item Options Help Text Comments
Assert NMI on SERR
Enabled
Disabled
On SERR, generate an NMI and log an error.
Note: [Enabled] must be selected for the Assert NMI
on PERR setup option to be visible.
Assert NMI on PERR
Enabled
Disabled
On PERR, generate an NMI and log an error.
Note: This option is only active if the Assert NMI on
SERR option is [Enabled] selected.
Resume on AC
Power Loss
Stay Off
Last state
Reset
System action to take on AC power loss recovery.
[Stay Off] - System stays off.
[Last State] - System returns to the same state before
the AC power loss.
[Reset] - System powers on.
Clear System Event
Log
Enabled
Disabled
If enabled, clears the System Event Log. All current
entries will be lost.
Note: This option is reset to [Disabled] after a reboot.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
If enabled, the BIOS programs the BMC watchdog
timer for approximately 6 minutes. If the BIOS does
not complete POST before the timer expires, the BMC
resets the system.