EasyManuals Logo

Intel S2600CO Family User Manual

Intel S2600CO Family
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
Appendix F: POST Code Diagnostic LED Decoder Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
146
Checkpoint
Diagnostic LED Decoder
Description (with MRC Internal Minor Code)
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
disabled due to hardware memtest error.
03h = No memory installed. All channels are disabled.
E9h
1
1
1
0
1
0
0
1
Memory is locked by Intel
®
Trusted Execution Technology
and is inaccessible
EAh
1
1
1
0
1
0
1
0
DDR3 channel training error
01h = Error on read DQ/DQS (Data/Data Strobe) init
02h = Error on Receive Enable
03h = Error on Write Leveling
04h = Error on write DQ/DQS (Data/Data Strobe
EBh
1
1
1
0
1
0
1
1
Memory test failure
01h = Software memtest failure.
02h = Hardware memtest failed.
03h = Hardware Memtest failure in Lockstep Channel
mode requiring a channel to be disabled. This is a fatal
error which requires a reset and calling MRC with a
different RAS mode to retry.
EDh
1
1
1
0
1
1
0
1
DIMM configuration population error
01h = Different DIMM types (UDIMM, RDIMM, LRDIMM)
are detected installed in the system.
02h = Violation of DIMM population rules.
03h = The 3rd DIMM slot cannot be populated when QR
DIMMs are installed.
04h = UDIMMs are not supported in the 3rd DIMM slot.
05h = Unsupported DIMM Voltage.
EFh
1
1
1
0
1
1
1
1
Indicates a CLTT table structure error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600CO Family and is the answer not in the manual?

Intel S2600CO Family Specifications

General IconGeneral
BrandIntel
ModelS2600CO Family
CategoryServer Board
LanguageEnglish

Related product manuals