13
4.5. Monitoring on/off fence
PGM2 is a dry contact that is activated when there is activation or deactivation of the fence system, that
is, if it is connected in the central area, it will send a trip and restoration to the monitoring company. For
connection, follow the procedure:
» Connect two wires to the PGM2 and COM terminals and connect them to the control panel’s zone
connection. This zone must be congured as 24h in order for the control panel to send a 24 hour zone
trigger signal and 24 hour zone restoration even when the control panel is disabled.
4.6. LED output
This output is used to indicate activation and deactivation when the electric fence is in a non-visible loca-
tion. To use it, simply place a 5 Vdc LED with a maximum current of 20 mA on the LED+ and LED- outputs.
This lit LED indicates that the fence shock or alarm is activated.
Note: it is not possible to measure this LED output with a multimeter as it is a pulsating output.
4.7. Battery start
When feeding the electrier only from the battery, it will not be possible to activate the pulse emission
from the fence, when trying to activate it, it will only emit 4 beeps on the siren and will deactivate
automatically, for safety reasons.
In order to activate the electrier, powered only by the battery, it will be necessary to perform the
following steps:
1. Press the Start button;
2. Activate the electric fence.
Note:
after pressing the Start button, the fence will wait for 5 seconds to be activated. After this time
the process will have to be repeated from the beginning. Battery starting is only required when the
product has been completely removed from power. After being connected to AC mains, the product will
work normally on battery.
4.8. Activation and deactivation through PGM
This product can be activated or deactivated through a PGM. Follow the instructions below:
» Connect the Z1 terminal of the electric fence to the PGM terminal of the control panel and the COM
terminal to the AUX - of the control panel. When the PGM is turned on, the electric fence will be
activated. When the PGM is turned off, the electric fence will be deactivated.