5. Installation completion
Program a key on the remote to turn on the fence.
5.1. Fence tension adjustment
1. To prevent sparking, adjust the power jumper according to the perimeter;
2. After all the wires are connected, go through the entire length of the fence, checking the stretch of
the wires (they should have no belly) and the splicing points, including sensor wires, if any;
3. Make sure that there is no vegetation (branches or leaves) too close to the fence, as this can cause
leaks and the microprocessor will perform a wrong learning process, causing undue triggers;
4. Activate the fence with shock and check its entire length for possible leaks (sparking);
5. Deactivate the fence using the remote control and eliminate the causes;
6. Turn it back on and learn the perimeter of the fence;
7. Simulate a fence break, turn it on and the siren should go off. Turn it off;
8. Simulate a short circuit with a wire, connecting the fence to the ground wire, turn it on and the siren
should go off. Turn it off;
9. Simulate a leak, connect a wire to the fence and to the other end, leave it very close to the ground
cable, about a few millimeters, turn it on and the siren should go off after N fault pulses elapse
(factory default: 8 fault pulses ). Turn it off.
6. General reset
If the High Power ELC 5002/ELC 5003 and ELC 5112 fences are turned on and it is not possible to use
the remote control, the only means available to turn off the fence is through a General System Reset. To
perform the General Reset, follow the procedure:
1. Hold down the Start and C keys. Remote;
2. All LEDs will ash quickly indicating that the Master Reset has been performed;
3. After General Reset the electric fence will return to factory default.
4. It is now possible to program another remote control.
Note:
»
This operation also erases all registered wireless devices.
»
For the procedures of items 1, 2 and 3 to work, the fence must be disarmed. With the fence
set up, before performing item 1, it is necessary to remove the power and re-feed it, following