26
4.25. Clear all programmed sensors
1. Set the Power jumper (JP1) to the Low position;
2. Press the Sector key and the Zone LED will light up. Press and hold the key for approximately 5 secon-
ds until the Fence and Zone LEDs ash indicating that the sensors have been cleared.
4.26. Siren beep activation/deactivation
1. Place the Power jumper (JP1) in the Medium (disconnected) position;
2. Press the Sector key and the On, Fence and Zone LEDs will light or ash. If the LEDs light, the siren
beep programming has been congured, if the LEDs ash the siren beep programming has been
congured.
4.27. Testing wired or wireless sensors and remote control
1. This function is used to facilitate testing of sensors/controls during installation. When activated, the siren
beeps whenever a sensor or remote control is activated. For example, in the case of an auto switch installed
in a door, a beep will sound when the door is opened or closed.
2. Place the Power jumper (JP1) in the Medium (disconnected) position;
3. Press the Start key.
When the fence is in test mode the On LED will ash slowly. To exit test mode, press the Start key again
and the Enabled LED will go out.
4.28. Siren time change
1. The factory default siren time is 15 minutes. This is the time the siren stays on after a violation occurs and
can be reprogrammed to a value between 01 and 99 minutes. To program, follow the procedure:
2. Place the Power jumper (JP1) in the High position;
3. Press and hold the Departure key. The Enabled, Fence and Zone LEDs will light for approximately 5 seconds
and then go out. After this time, the On LED will ash every 1 second. Each LED ash corresponds to 1
minute of siren time.
4.29. Failed Pulse Amount Programming
1. Set the Power jumper (JP1) to the Low position;
2. Press the Start key. The Fence LED will light for approximately 5 seconds and after this time will ash
every 1 second. Each blink corresponds to 1 more faulty pulse.
Note: the minimum amount of failed pulse is 5 pulses and the maximum amount is 36 pulses, so cou-
nting starts with the rst pulse. When the countdown reaches 36, the Enabled LED will light up ending
the countdown. Release the key so the LED goes out. If you release the key within the rst 5 seconds,
the number of failed pulses will be 5 pulses.
The factory default quantity is 8 failed pulses.
Arming/disarming the fence by the alarm sector