TL6000, Users
Rev L, June 2008
Page 18 of 22
Calibrating the weight accuracy
Note: At this time the scale saves any changes that have been made.
Note: A check is then made to see whether or not the calibration blocking strap
is in place. If the blocking strap is in place, the scale shows CALSt
CALStCALSt
CALSt for a few
seconds and then returns to normal weighing.
8) Assuming the calibration strap was removed, the display will read ‘L0Ad0
L0Ad0L0Ad0
L0Ad0’.
With no weight applied to the scale, press ZERO and PEAK together.
9) The display will read ‘L0Ad1
L0Ad1L0Ad1
L0Ad1’. Apply the first weight. When the weight is
stable press one of the arrow keys. The display will read ‘H0Ld
H0LdH0Ld
H0Ld’ while the
scale acquires the first weight. After this, enter the value of the applied
weight. Press ZERO and PEAK together to save the value and advance to
Load 2.
10) The display will read L0ad2
L0ad2L0ad2
L0ad2’. Apply the second weight. When the weight is
stable press one of the arrow keys. The display will read ‘H0Ld
H0LdH0Ld
H0Ld’ while the
scale acquires the second weight. After this, enter the value of the applied
weight. Press ZERO and PEAK together to save the value and advance to
Load 3.
11) The display will read L0Ad3
L0Ad3L0Ad3
L0Ad3’. Apply the third weight. When the weight is
stable press one of the arrow keys. The display will read ‘H0Ld
H0LdH0Ld
H0Ld’ while the
scale acquires the third weight. After this, enter the value of the applied
weight. Press ZERO and PEAK together to save the value. The display will
read ‘SAvE
SAvESAvE
SAvE’ for a few seconds and advance to Load 4.
12) The display will read L0Ad4
L0Ad4L0Ad4
L0Ad4’. Apply the fourth weight. When the weight is
stable press one of the arrow keys. The display will read ‘H0Ld
H0LdH0Ld
H0Ld’ while the
scale acquires the third weight. After this, enter the value of the applied
weight. Press ZERO and PEAK together to save the value. The display will
read ‘SAvE
SAvESAvE
SAvE’ for a few seconds and advance to Load 5.
13) The display will read L0Ad5
L0Ad5L0Ad5
L0Ad5’. Apply the fifth weight. When the weight is
stable press one of the arrow keys. The display will read ‘H0Ld
H0LdH0Ld
H0Ld’ while the
scale acquires the third weight. After this, enter the value of the applied
weight. Press ZERO and PEAK together to save the value. The display will
read ‘SAvE
SAvESAvE
SAvE’ for a few seconds and return to measurement mode.
14) Verify calibration.
15) Replace the cal strap to protect against accidental entry into the calibration
routine in the future.
16) Calibration complete.

Related product manuals