42 NX-595E Installation Manual
Location 17 - Divert Phone Number Three (3)
The third Divert phone number is programmed in Location 17
Call divert phone number 3 will be dialed if call divert phone number 2 is busy, when a call is
initiated from an outdoor station. The outdoor station must be interfaced with the NetworX
security system via the NX-595E. The NetworX security system must also be in the armed
condition
15 = Pulse dialing – in the segment where pulse dialing should begin
14 = Indicates the end of the phone number
13 = Creates a four second delay
12 = #
11 =
*
Segments 1-20 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14
Location 18 - Zone Starting Number
Location 18 is used to enter the starting zone number of the additional zones
on the NX-595E. The two zones can also be zone doubled, please refer to
Location 1 to enable the zone doubling feature. 0 = Disabled
Data Zones Data Zones Data Zones Data Zones
9 = 9 - 12 41 = 41 - 44 73 = 73 - 76 105 = 105 -108
17 = 17 - 20 49 = 49 - 52 81 = 81 - 84 113 = 113 - 116
25 = 25 - 28 57 = 57 - 60 89 = 89 - 92 121 = 121 - 124
33 = 33 - 36 65 = 65 - 68 97 = 97 - 100
Note: Additional zones are only available on the NX-8E. This feature is not
available for NX-4 or NX-8 panels.
Segment 1
Location 19 - IP Feature Options
Location 19 is used to set required network settings.
Enable DHCP: DHCP or Dynamic Host Configuration Protocol, is a computer
network protocol used by devices to obtain configuration information for
operation in an Internet Protocol network. This protocol reduces system
administration workload, allowing networks to add devices with little or no
manual intervention.
Require SSL: SSL or Secure Sockets Layer is a security protocol for
communication over networks such as the Internet and reduce the chance of
someone eavesdropping on your interaction with the security system. If
Require SSL is selected then port 80 (standard http:) will be disabled and you
must use https: which by default is port 443. If Require SSL is not enabled
then you can connect using either http: on port 80 or https: on port 443.
Enable Web page updates without a login: When enabled, allows updating
of the NX-595E Configuration Server's web pages via FTP. Normally disabled.