NX-595E Installation Manual 43
Enable Ping in the run mode: The “ping” command is always functional
whilst the NX-595E is in program mode and is defaulted to NOT operate whilst
the NX-595E is in the normal run mode. Enable this option to allow the NX-
595E to respond to "ping" commands in normal operation. For security
reasons it is recommended this option remain disabled during normal
operation.
Enable periodic update of clock via internet: The NX-595E will check its
internal and use the internet to compare it against GMT time. This is done
every 15min and will update itself if the variance is greater than 3 minutes.
Enable web programming: When enabled a user can access Network
settings, location list, Outputs and IP reporting via the NX-595E's web pages.
Otherwise the NX-595E will need to be in program mode to access these
additional features. By default this is off to prevent an end-user access to
these additional menus.
Enable NetworX protocol server: Disabled by default, do not change.
Enable Service: Enabled by default. Enabling this option allows you to use
the app (xConnect).
Segment 1
(1) Enable DHCP
(2) Require SSL
3 Enable Web page updates without a login
4 Enable Ping in run mode
5 Enable periodic update of clock via internet
6
Enable Web programming of Network settings, location list,
Outputs and IP reporting without NX-595E needing to be in
program mode
7 Enable NetworX protocol server
8 Enable Service
Segment 2 Reserved
Location 20 - IP Gateway
The 4 segments in Location 20 are used to set the IP address of the networks gateway.
In homes, the gateway is usually the Internet Service Provider (ISP) device that connects the
user to the internet, such as a DSL or cable modem.
In an enterprise system, the gateway is the node that routes the traffic from a workstation to
another network segment. The default gateway is commonly the node connecting the internal
networks and the outside network (Internet).
Segments 1 - 4