Simon XT Installation Manual 9
Type
Name/application
Siren type
Delay
Restoral
Supervised
Active in
arming
levels
10
Entry/exit delay: A delay that requires a standard
delay time. Chime.
Intrusion
S
Y
Y
24
13
Instant perimeter: Exterior doors and windows.
Chime.
Intrusion
I
Y
Y
24
14
Instant interior: Interior door.
Intrusion
F
Y
Y
234
15
Instant interior: Interior PIR motion sensor.
Intrusion
F
Y
Y
234
16
Instant interior: Interior door.
Intrusion
F
Y
Y
34
17
Instant interior: PIR motion sensor and sound
sensor.
Intrusion
F
N
Y
34
18
Instant interior: Cross-zone PIR motion sensor.
Intrusion
F
N
Y
34
19
Delayed interior: Interior doors that initiate a delay
before going into alarm.
Intrusion
S
Y
Y
34
20
Delayed interior: PIR motion sensor that initiates a
delay before going into alarm.
Intrusion
S
N
Y
34
21
Local instant interior: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Intrusion
I
Y
Y
1234
22
Local delayed interior: Same as group 21, plus
activation initiates a delay before going into alarm.
No report.
Intrusion
S
Y
Y
1234
23
Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Emergency
I
Y
Y
01234
24
Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. Sirens
shut off at restoral. No report.
Emergency
I
Y
Y
01234
25
Local special chime: Notify the user when a door is
opened.
Three
beeps
I
N
Y
01234
26
Fire: 24-hour fire, rate-of-rise heat, and smoke
sensor.
Fire
I
Y
Y
01234
27
Lamp control or other customer feature. No report.
Silent
I
Y
Y
012345
28
PIR motion sensor, sound sensor, or pressure mat.
RF thermostat. No report
Silent
I
N
Y
01234
29
Auxiliary: Freeze sensor.
Trouble
beeps
I
Y
Y
01234
32
PIR motion sensor or sound sensor. No report.
Silent
I
N
N
01234
34
Carbon monoxide alarm.
Emergency
I
Y
Y
01234
35
Entry/exit delay interior PIR motion
Intrusion
S
N
Y
234