48 Simon XT Installation Manual
Function
Default
Description
HW1 function
1
Determines how the HW1 I/O output will function:
Off = no output
1 = interior siren output
2 = output activated when armed
3 = output activated when disarmed
4 = fail to communicate output, activates when fail to
communicate condition occurs (the fail to communicate option
must be on)
5 = alarm output activated when panel is in alarm
24-hour clock
Off
Determines whether the panel uses a 24-hour clock (on), or a
12-hour clock (off).
Siren options
Table 21 below describes the Siren Options menu.
Table 21: Siren Options menu
Function
Default
Description
Piezo beeps
On
Determines whether the panel piezo produces beeps based
on system activity (on), or is silent (off).
Panel voice
On
Determines whether the panel announces arming level
changes (on), or not (off).
Panel piezo
alarm
On
Determines whether the panel piezo emits alarm sounds (on),
or not (off).
Trouble beeps
On
Determines whether the panel and hardwired interior sirens
sound six beeps every minute when a trouble condition
occurs (on), or not (off). The following conditions cause
trouble beeps: AC power failure (when AC power failure
report is on) low CPU battery, sensor failure (supervisory),
sensor trouble (low battery, tamper, etc.), fail to communicate,
restoration of power, no activity timer has timed out (trouble
beeps continue for 5 minutes and if the panel does not see
activity, trouble beeps stop and the panel reports no activity to
the central station).
You can silence trouble beeps by arming or disarming the
system or by pressing the STATUS button. Trouble beeps
resume later if the trouble condition is not cleared.

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing
Dimensions IconDimensions
height4 1/16 in.
width1 7/8 in.