Simon XT Installation Manual 39
Phone options
Table 13: Phone Options menu
Function
Default
Description
Man phone test
On
Determines whether you can perform a manual communication
test to verify communication to a central station/voice dial (on),
or not (off). If you have all four phone numbers programmed, it
should send a test report to all four before showing that the test
is okay.
FTC
On
Determines whether the panel and interior sirens sound trouble
beeps if it is unable to successfully send a report to a central
station (on), or not (off).
DTMF dial
On
Determines whether the panel uses DTMF (on) or pulse (off) for
dialing programmed phone numbers.
300 bps enabled
On
Determines whether the baud rate used by the panel for central
station communication is 300 bps (on), or 110 bps (off).
Ring hang ring
1
Determines when the panel answers a remote phone access or
Enterprise call. Depending on whether an answering machine
exists at the panel location, offsite access to the panel can be
done with a series of phone calls or just one. For offsite access
where an answering machine does not exist, the user or
Enterprise operator simply calls the panel location once and
listens for 10 rings. The panel should answer after the tenth
ring.
For offsite access where an answering machine exists, the user
or Enterprise operator must call the panel location, and then let
the phone ring once and hang up. Wait at least 10 seconds but
not more than 40, and then call the panel location again. The
panel should answer on the first ring.
Ring/hang/ring setting number and sequence of rings after
which the panel answers:
1 = Ring/hang/ring or ten rings
2 = Ring/hang/ring/hang/ring or ten rings
3 = Ring/hang/ring/hang/ring/hang/ring or ten rings
4 = Ten rings
5 = Ring/hang/ring
6 = Ring/hang/ring/hang/ring
7 = Ring/hang/ring/hang/ring/hang/ring
Off = Disabled, no remote (offsite) access

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing
Dimensions IconDimensions
height4 1/16 in.
width1 7/8 in.