Simon XT Installation Manual 33
Menu navigation
Each menu contains a list of options and/or submenus. Press the scroll up/down
buttons to navigate up and down the list of options and submenus in that menu.
Pressing the Enter key after navigating to an option selects that option for editing
and flashes the current value. Pressing the Enter key after navigating to a
submenu enters that submenu, making a new list of options accessible. Pressing
STATUS exits a menu and goes to the next higher level.
Programming options are arranged in a menu structure as outlined in Table 10
below. The top menu contains several features, as well as the System
programming menu. When accessing the System programming or System tests
menu, the panel prompts you to enter an access code. To continue, enter the
dealer code or installer code, then press Enter.
To program an option, first navigate to that option until it is displayed, then press
Enter. The option value will start flashing, indicating that it is ready to be
changed. Use the scroll keys or enter a numerical value to change the option,
then press the Enter key to save the change.
Table 10: Simon XT menu structure
Set Clock (system time)
Set Date
Chime
Special Chime
System Tests
Sensor Test
Communication Test
System Download
System Programming
Access Codes
Dealer Code
Master Code
User Codes 1 to 8
Duress Code
Security
Downloader Enable
Phone Numbers
Phone Number 4
Timers
Latchkey Time
Siren Options
Panel Piezo Beeps
Panel Voice
Panel Piezo Alarms
Status Beep Volume
Speaker Volume

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing