42 Simon XT Installation Manual
Table 15: Device programming
Press the button on the top of the sensor (cover removed) or trip the
tamper.
Press the button on the back of the sensor (mounting plate
removed) or trip the tamper.
Trip the tamper, press the test button, remove the detector from its
base, or put the smoke detector into alarm.
Separate the sensor from its magnet.
Plug in the module, wait 5 to 7 seconds, and press and hold the test
button for nine beeps.
Trip the tamper or press and hold the button on the top of the
sensor (cover removed) until the control panel confirms
programming. If you do not hold the button down long enough, the
system will report the sensor as open.
Press the help button until the light blinks.
Press the emergency buttons.
Press the Lock and Unlock buttons at the same time.
Do the following:
1. Press the Unlock button twice and hold it the third time. The light
button flashes three times.
2. Press the Unlock button once and hold it the second time. The
light button flashes twice.
3. Press and hold the Unlock button. The light button flashes once.
Hold the button until the flashing stops.
Edit sensors
You can use this menu to change the group or name of a sensor that is already
in panel memory. The procedure is very similar to the procedure to program
sensor information after a sensor is learned in. Pressing Disarm while editing
sensor text deletes all text for that sensor.
Note: If you are installing a sensor on a gun case, jewelry box, or a similar case,
and the sensor is active in level one, you must subdisarm to avoid putting the
panel into alarm when the sensor and the magnet are separated.
Reporting
Table 16 on page 43 and Table 17 on page 44 describe the Reporting menu.