Simon XT Installation Manual 15
Function
Default
Delete
Range
Access
code
Installer
settings
Alarm cancel
6 minutes
Off
6 to 255 minutes,
Off
D, I
RF timeout
12 hours
12 hours
2 to 36 hours
D, I
Fail to open time
Off
Off
12:00 midnight to
11:59 PM, Off
D, I
Fail to close time
Off
Off
12:00 midnight to
11:59 PM, Off
D, I
Siren timeout
5 minutes
Off
2 to 254 minutes,
Off
D, I
Arming LED
shutdown
Off
Off
On/Off
D, I
Unvacated premises
On
Off
On/Off
D, I
Smoke supervision
Off
Off
On/Off
D, I
Touchpad options menu
Key fob no delay
Off
Off
On/Off
D, I
Panic alarms
On
Off
On/Off
D, I
Remote touchpad
arming
Off
Off
On/Off
D, I
System options menu
RF jam detect
Off
Off
On/Off
D, I
Demo mode
Off
Off
On/Off
D, I
HW1 function
1
Off
1, 2, 3, 4, 5, or Off
D
24-hour clock
Off
Off
On/Off
D, I
Siren options menu
Panel piezo beeps
On
Off
On/Off
D, I, M
Panel voice
On
Off
On/Off
D, I, M
Panel piezo alarms
On
Off
On/Off
D, I, M
Trouble beeps
On
Off
On/Off
D, I
Voice chime
Off
Off
1, 2, 3, or Off
D, I
Status beeps volume
7
7
1 to 10
D, I, M
Hardwired siren
supervision
Off
Off
On/Off
D, I
Speaker volume
8
8
1 to 8
D, I, M
Panel silent police
panic
Off
Off
On (silent), Off
(audible)
D, I
Panel tamper alarm
Off
Off
On/Off
D, I