To setup VCA alarm actions:
1. From the menu toolbar, click Camera Setup > VCA.
2. Select the camera for which to set up the VCA alarm.
3. Check the Enable VCA Alarm box to enable the feature.
4. Select the desired VCA type.
5. Select the recording schedules for the selected VCA.
6. Click the Actions button to define which actions are required with each selected
VCA event from each camera.
In the Actions window, click the Trigger Channel tab and then select the cameras
to be triggered for recording when an alarm is detected. Click Apply to save the
settings and then OK to return to the VCA window.
7. Select the arming schedules for the VCA event.
In the Actions window, click the Arming Schedule tab and select the day of the
week and the time periods during the day when motion can be recorded. You can
schedule up to eight time periods in a day. Default is 24 hours.
Note: The time periods defined cannot overlap.
Click Apply to save the settings. Click Copy to copy these settings to other days of
the week. Click OK to return to the VCA window.
8. Select the response method to a VCA event.
In the Actions window, click the Actions tab to define the method by which you want
the recorder to notify you of the alarm: Full-screen Monitoring, Enable Alarm Audio,
Notify Alarm Host, Send Email, Play Audio File, and Trigger Alarm Output. See
page 98 for the description of alarm notification types. More than one option can be
selected.
Click Apply to save the settings and then OK to return to the VCA window.
9. Select the PTZ camera function required in response to a VCA alarm.
In the Actions window, click the PTZ Linking tab. Select the PTZ camera and enter
the number of preset, preset tour or shadow tour that is triggered when the alarm is
detected.
10. Click Apply to save all the settings and then click Exit to return to live view.
Configure PTZ settings
Use the PTZ Setup menu to configure only analog PTZ dome cameras. Each analog
camera must be set up individually. The cameras must be configured before they can