CK71 Service Work Instructions
The bottom housing will need to be removed to access internal assemblies or if it needs to be replaced. The bottom
housing is secured with 10 screws. There is a different spare bottom housing for each scan engine option due to
differences in the factory installed shock mounts and scan windows.
Tools Required
Parts Required
HOUSING,BOTTOM,ASSY C2, EX25 SPARE
HOUSING,BOTTOM,ASSY C2, EV12 SPARE
HOUSING,BOTTOM,ASSY C2, EA30 SPARE (and N5603)
SCREW 4-40X1/2 PH TORX W/NYL CRES ROHS
SCREW 2-56 X 7/16 PH TORX W/NYL CRES ROH
Kapton Tape (1.39 inches)
Adhesive, vibrator wiring
NOTE: A new bottom housing will not have any labeling on it
Removal
1. Remove the stylus from its storage slot in the back cover.
2. Remove the uSD/SIM card slot access cover.
3. Remove 10 screws. Discard the screws. The screws have a one time use seal. New screws must be used when
reinstalling the bottom housing.