CK71 Service Work Instructions
Different main logic boards have been used to produce CK71’s since it was introduced. Be sure to replace a
main logic board with one from the same 234-xxx-xxxx series as already installed in the unit being repaired. See
table below:
CK71AA2xxxxxxxxx
CK71AB2xxxxxxxxx
CK71AA4xxxxxxxxx
CK71AB4xxxxxxxxx
CK71AA6xxxxxxxxx
CK71AB6xxxxxxxxx
Tools Required
Phillips screwdriver with #0 tip
Parts Required
MLB, 802.11 ABGN Nexgen CN70 CK7x (use for 600MHZ configurations)
MLB,1GHZ Wodsp CN70 CK7x (use for original 1GHZ configurations)
MLB,Refresh Assy CN70 CK7X (use for refresh program 1GHz configurations)
screw,2-56,torx drive,wafer head,custom
GROUND PLATE, SCAN ENGINE, EX25
GROUND PLATE ASSY, EA30/EV12
Ground plate assy, N5603, PASION
Custom Screw, #2-56x3.4mm Wafer Hd, RoHS
Removal
1. Remove the bottom housing assembly (refer to Bottom Housing operation).
2. Remove the core assembly from the top housing (refer to Core Assembly operation).
3. Remove the scan bracket assembly (refer to scan bracket assembly operation).
4. Remove the display assembly (refer to LCD Display & Touch Panel operation).
5. Disconnect the WLAN antenna coax cable from J4 on the main logic board.
6. Using a T7 torx driver remove four screws that attach the main logic board to the magnesium frame.