Chapter 4 — Enabling and Configuring Symbologies
90 SR60 Scanner Programmer’s Reference Manual
Label Length Format
The next two sections explain how to set the Interleaved 2 of 5
Label Length Format to either the Variable Length or Fixed
Length Format.
Variable Length Format
You can set the Interleaved 2 of 5 symbology to Variable Length
Format.
To set the Interleaved 2 of 5 Variable Length Format
1 Identify the minimum length setting you want to make. You
may choose any even number between 02 to 50
characters.
2 Scan the SET bar code.
3 Scan the Enable Variable Length Format bar code.
4 Scan the Set Minimum Label Length bar code.
5 Using the Digits bar codes on page 93, scan the digits to set
the minimum label length you identified in Step 1.
Don’t Transmit ---------
Transmit ---------
END-----------------------------------
Note: For this symbology, the scanner decodes up to 50
characters, but the actual length read varies depending upon
the interface type, bar code physical size, and print quality.