Chapter 4 — Enabling and Configuring Symbologies
SR60 Scanner Programmer’s Reference Manual 133
To set the MSI/Plessey to read Variable Length Format
1 Identify the minimum length setting you want to make. The
selectable range is 04 to 16 characters.
2 Scan the SET bar code.
3 Scan the Enable Variable Length Format bar code.
4 Scan the Set Minimum Label Length bar code.
5 Using the Digits bar codes on page 135, scan the digits to set
the minimum label length you identified in Step 1.
6 Scan the END bar code.
Fixed Length Format
The scanner offers the option of requiring MSI/Plessey labels to
have one or two fixed length(s) in the Fixed Label Format.
Note: To set a label length less than ten, you must scan a zero
digit first and then the length digit (such as 04, 06, or 08).
Variable Length
SET-------------------------------------
Enable Variable
Length Format ---------
Set Minimum
Label Length ---------
END------------------------------------