Assembly
9006 Hybrid Control for RollerDrive
Installing the 9006 Hybrid Control in a conveyor system
Use the 9006 as a template and mark the center of the two mounting
holes. For the distance between the holes, see "Dimensions", page 7.
Drill two ø 5.6 - 6 mm (0.22 - 0.24 in) mounting holes at the marked spots.
Insert the button head screws in the holes on the opposite side the
9006 is to be mounted.
Install the 9006 to the frame with the screws protruding through the
mounting holes.
Slip the nuts to the screws and tighten.
Ensure that there is a ground path between the 9006 and the conveyor
frame it is mounted to.
Electrical installation
The connector supplied with the RollerDrive EC1xx mates up with the header on
the 9006.
The connectors "Power input and I/O terminal" and "Sensor connection" are cage
clamp terminals.
To actuate the cage clamp, use the supplied tool or insert a small screwdriver.
Plug in the RollerDrive connector.
Plug in the peer-to-peer connection cable, if applicable.
Hint
The 9006 and conveyor frame should be at the same potential referenced
to earth ground.