Goodrive300-01 inverter for air compressor Function parameters
-56-
Detailed instruction of parameters
This parameter is used to control the internal braking
pipe inside the inverter.
0: Disabled
1: Enabled
Note: Only apply to internal braking pipe.
After setting the original bus voltage to brake the
energy, adjust the voltage appropriately to brake the
load. The default value changes with the voltage
level.
The setting range: 200.0~2000.0V
In order to prevent customers set the value is too
large, it is recommended setting range:
0: Normal mode
1: The fan keeps running after power on
0x00~0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 2k if it exceeds 2k at low
speed
1: Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at low
speed
2: No limit
LED ones
0: Invalid
1: Valid
LED tens
0: Light overmodulation; in zone 1
1: Heavy overmodulation; in zone 2
0x000~0x1223
LED ones: frequency enable selection
0: Both ∧/∨ keys and digital potentiometer
adjustments are valid