Goodrive300-01 inverter for air compressor Function parameters
-66-
Detailed instruction of parameters
inverter will output underload pre-alarm.
Setting range of P11.11: 0~P11.09
Setting range of P11.12: 0.1~3600.0s
Underload
pre-alarm
detection time
Output terminal
action during fault
Select the action of fault output terminals during
undervoltage and automatic reset.
0x00~0x11
LED ones:
0: Action during undervoltage
1: No action during undervoltage
LED tens:
0: Action during the automatic reset
1: No action during the automatic reset
Speed deviation
detection
0.0~50.0%
Set the speed deviation detection.
Speed deviation
detection time
Set the speed deviation detection time.
Setting range of P11.15: 0.0~10.0s
Automatic
frequency
decreasing at
voltage drop
0: Invalid
1: Valid; when the grid voltage drops to the rated
voltage, the inverter will decrease the frequency
automatically to ensure the rated output torque.
0:Asynchronous motor
1:Synchronous motor
Note: Switch the current motor by the switching
channel of P08.31.
Set the parameters of the
controlled asynchronous
motor.
To guarantee the control
performance, be sure to set
0.01Hz~P00.03 (Max.
output frequency)