Goodrive300-01 inverter for air compressor                                                                Function parameters 
-71- 
Detailed instruction of parameters 
Source  current  is  the  positioning  current  of  the 
magnetic  pole  position.  Source  current  1  is  valid 
under  the  frequency  point  of  current  shifting. 
Increasing the value can raise the starting torque. 
Setting  range:  0.0%~100.0%  (rated  current  of  the 
motor) 
Source current is directional current of the magnetic 
pole  position.  Source  current  2  is  valid  under  the 
frequency point of current shifting. There is no need 
to modify the value generally.   
Setting  range:  0.0%~100.0%  (rated  current  of  the 
motor) 
Shift frequency of 
source current   
Valid  frequency  shifting  point  between  source 
current 1 and current 2.   
Setting  range:  0.00Hz~P00.03  (Max.  output 
frequency) 
Superposition 
frequency 
(reserved) 
Pulse 
superposition 
voltage 
0.0~300.0% (rated voltage of the motor) 
Maladjustment 
detection time   
Adjust  the  response  of  anti-maladjustment.  Bigger 
load inertia may increase the value, but the response 
will be slower.   
Setting range: 0.0~10.0s 
High frequency 
compensation 
coefficient   
When  the  motor  speed  is  faster  than  the  rated 
speed, the parameter is valid, if vibration occurs to 
the motor, please adjust the parameter.   
Setting range: 0~100.0% 
Braking current of 
short-circuit   
When P01.00=0 during the starting of the inverter, 
set P13.14 to a non-zero value to enter the short