Goodrive300-01 inverter for air compressor Function parameters
-71-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P13.02
Source current 1
Source current is the positioning current of the
magnetic pole position. Source current 1 is valid
under the frequency point of current shifting.
Increasing the value can raise the starting torque.
Setting range: 0.0%~100.0% (rated current of the
motor)
20.0%
P13.03
Source current 2
Source current is directional current of the magnetic
pole position. Source current 2 is valid under the
frequency point of current shifting. There is no need
to modify the value generally.
Setting range: 0.0%~100.0% (rated current of the
motor)
10.0%
P13.04
Shift frequency of
source current
Valid frequency shifting point between source
current 1 and current 2.
Setting range: 0.00Hz~P00.03 (Max. output
frequency)
30.00 Hz
P13.05
Superposition
frequency
(reserved)
200~1000Hz
500Hz
P13.06
Pulse
superposition
voltage
0.0~300.0% (rated voltage of the motor)
40.0%
P13.07
Reserved
0~65535
0
P13.08
Control parameter
1
0~65535
0
P13.09
Control parameter
2
0~655.35
2.00
P13.10
Reserved
0~65535
0
P13.11
Maladjustment
detection time
Adjust the response of anti-maladjustment. Bigger
load inertia may increase the value, but the response
will be slower.
Setting range: 0.0~10.0s
0.5s
P13.12
High frequency
compensation
coefficient
When the motor speed is faster than the rated
speed, the parameter is valid, if vibration occurs to
the motor, please adjust the parameter.
Setting range: 0~100.0%
60.0%
P13.13
Braking current of
short-circuit
When P01.00=0 during the starting of the inverter,
set P13.14 to a non-zero value to enter the short
0.0%