Goodrive300-01 inverter for air compressor Function parameters
-78-
Detailed instruction of parameters
Lower limit of
loading running
frequency
P18.12~P00.04 (upper limit of running frequency)
During adjusting, allow to output the minimum
running frequency when the pressure is above the
set pressure and below the unloading pressure.
Non-load running
frequency
P01.15~P18.11 (Lower limit frequency of loaded
running)
The allowable output running frequency for air
compressor at no load.
0~3600s
Enter into hibernation when non-load running
exceeds the set time.
0~3600s
At stop, run by non-load frequency and then stop
after the delay time.
0~3600s
The master runs for the time before loading
operation.
0~3600s
After stop, the set time is needed for restart.
0.00~ P18.04
Pre-alarm when the air supply pressure is detected
above the set pressure.
0.00~ P18.04
Alarm and stop when the air supply pressure is
detected above the set pressure.
-20~150°C
Pre-alarm when the exhaust temperature is detected
above the set temperature.
-20~150°C
Alarm and stop when the exhaust temperature is
detected above the set temperature.
Low temperature
protection
threshold
-20~150°C
When the exhaust temperature is detected below the
set value, display the temperature is too low, prohibit
starting the air compressor and alarm.
Power correction