Goodrive300-LIFT series inverter Expansion cards
-146-
Function
code
Name
Detailed parameter description
Default
value
Modify
P07.28
Type of current
fault
0: No fault
1: Inverter unit U phase protection (OUt1)
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection (OUt3)
4: ACC overcurrent (OC1)
5: DEC overcurrent (OC2)
6: Constant-speed overcurrent (OC3)
7: ACC overvoltage (OV1)
8: DEC overvoltage (OV2)
9: Constant-speed overvoltage (OV3)
10: Bus undervoltage (UV)
11: Motor overload (OL1)
12: Inverter overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
15: Overheat of the rectifier module (OH1)
16:Overheat fault of the converter module
(OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor autotune fault (tE)
21: EEPROM operation fault (EEP)
22: PID response offline fault (PIDE)
23: Brake unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
26: Panel communication fault (PCE)
27: Parameter uploading fault (UPE)
28: Parameter downloading fault (DNE)
29: PROFIBUS communication fault (E-DP)
30: Ethernet communication fault (E-NET)
31: CANopen communication fault (E-CAN)
P07.29
Type of last
fault
P07.30
Type of last but
one fault
P07.31
Type of last but
two fault
P07.32
Type of last but
three fault
P07.33
Type of last but
four