Goodrive350 series high-performance multi-function inverter Chapter 6
-131-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P02.15
Rated power of
synchronous
motor 1
0.13000.0Kw
Depend
on model
P02.16
Rated frequency
of synchronous
motor 1
0.01HzP00.03 (max. output frequency)
50.00Hz
P02.17
Number of pole
pairs of
synchronous
motor 1
1128
2
P02.18
Rated voltage of
synchronous
motor 1
01200V
Depend
on model
P02.19
Rated current of
synchronous
motor 1
0.86000.0A
Depend
on model
P02.20
Stator resistance
of synchronous
motor 1
0.001–65.53
Depend
on model
P02.21
Direct-axis
inductance of
synchronous
motor 1
0.01655.35Mh
Depend
on model
P02.22
Quadrature-axis
inductance of
synchronous
motor 1
0.01655.35Mh
Depend
on model
P02.23
Counter-emf
constant of
synchronous
motor 1
010000
300
P02.24
Initial pole
position of
synchronous
motor 1
(reserved)
0x00000xFFFF
0
P02.25
Identification
current of
0%50% (rated motor current)
10%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive350 Series and is the answer not in the manual?

INVT Goodrive350 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive350 Series
CategoryDC Drives
LanguageEnglish

Related product manuals