Goodrive350 series high-performance multi-function inverter Chapter 6
-190-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P17.26
Current running
time
Display current running time of the inverter.
Range: 065535min
0m
P17.27
Simple PLC and
current step
number of
multi-step speed
Display simple PLC and current step number of
multi-step speed
Range: 015
0
P17.28
Motor ASR
controller output
Display the speed loop ASR controller output value
under vector control mode, relative to the percentage
of rated torque of the motor.
Range: -300.0%300.0% (rated motor current)
0.0%
P17.29
Pole angle of
open-loop
synchronous
motor
Display initial identification angle of synchronous
motor
Range: 0.0360.0
0.0
P17.30
Phase
compensation of
synchronous
motor
Display phase compensation of synchronous motor
Range: -180.0180.0
0.0
P17.31
High-frequency
superposition
current of
synchronous
motor
0.0%200.0% (rated motor current)
0.0
P17.32
Motor flux linkage
0.0%200.0%
0.0%
P17.33
Exciting current
reference
Display the exciting current reference value under
vector control mode
Range: -3000.03000.0A
0.0A
P17.34
Torque current
reference
Display torque current reference value under vector
control mode
Range: -3000.03000.0A
0.0A
P17.35
AC incoming
current
Display the valid value of incoming current on AC
side
Range: 0.05000.0A
0.0A
P17.36
Output torque
Display output torque value, during forward running,
positive value is motoring state, negative value is
generating state; during reverse running, positive
value is generating state, negative value is motoring
state.
0.0Nm