Goodrive350 series high-performance multi-function inverter Chapter 5
-67-
Function
code
Name
Detailed parameter description
Default
value
keypad
P17.09
Motor output
torque
-250.0250.0%
0.0%
P17.15
Torque reference
value
-300.0300.0% (rated motor current)
0.0%
5.5.6 Motor parameter
Check the safety conditions surrounding the motor and load machineries
before autotuning as physical injury may occur due to sudden start of motor during
autotuning.
Although the motor does not run during static autotuning, the motor is stilled
supplied with power, do not touch the motor during autotuning; otherwise, electric
shock may occur.
If the motor has been connected to load, do not carry out rotary autotuning;
otherwise, misact or damage may occur to the inverter. If rotary autotuning is carried
out on a motor which has been connected to load, wrong motor parameters and
motor misacts may occur. Disconnect the load to carry out autotuning if necessary.
GD350 inverter can drive asynchronous motors and synchronous motors, and it supports two sets of
motor parameters, which can be switched over by multi-function digital input terminals or
communication modes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive350 Series and is the answer not in the manual?

INVT Goodrive350 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive350 Series
CategoryDC Drives
LanguageEnglish

Related product manuals