SPC Series Solar Pump Inverter Fault diagnosis and solution
-53-
Fault code
Fault type
Possible cause
Solution
OL3
Electronic
overload fault
The inverter reports
overload pre-alarm
according to the
setting.
Check the load and the
overload pre-alarm
points.
ETH1
To-ground
short-circuit fault 1
The output of the
inverter is short
circuited to the
ground.
There is a fault in the
current detection
circuit.
Check whether the
motor wiring is normal.
Replace the Hall
device.
Change the main
control board.
ETH2
To-ground
short-circuit fault 2
dEu
Speed deviation
fault
The load is too heavy
or stalled.
Check the load and
increase the detection
time if the load is
normal.
Check whether control
parameters are set
correctly.
STo
Mal-adjustment
fault
SM control
parameters are set
incorrectly.
Autotuned
parameters are not
accurate.
The inverter is not
connected to the
motor.
Check the load and
ensure the load is
normal.
Check whether control
parameters are set
correctly.
Increase the
mal-adjustment
detection time.
LL
Electronic
underload fault
The inverter reports
underload pre-alarm
according to the
setting.
Check the load and the
underload pre-alarm
points.
A-LS
Weak-light
pre-alarm
The sunlight is weak
or the PV module
configuration is
insufficient.
The device will
automatically run when
the light is sufficient.
Check whether the PV
module configuration is
sufficient.