- LIK50 Description & Installation
Issue 1.2.1
32
Table 4.4.1-1 MFIM50A Status LED Functions
LED DESIGNATION
LED STATUS FUNCTION - ON -
S1
Serial/TCP debug active
S2
Call Processing active
S3
Active data communication with Modules and IP Phones
S4
CPU active (100ms flashing)
VSF
VSF Active (Flashing)
FXO1
CO Port 1 In-use
FXO2
CO Port 2 In-use
FXO3
CO Port 3 In-use
FXO4
CO Port 4 In-use
VSF
FXS ports In-use
MODE Switch & Settings
MFIMs have a four (4) position DIP-switch identified as the MODE switch. The function of each
switch position is given in Table 4.4.1-2 below.
Table 4.4.1-2 MFIM50A MODE Switch Functions
Name
Contact
FUNCTION
ON
OFF
MODE
1
Database write protect
Protect
Unprotect
2
Boot mode protect
Enable
Disable
3
Registration
Allow registration
Deny Registration
4
initialization
Initialize DB on reset
Read Stored DB on reset
To enter data in the system’s database, the Write Protect switch must be in the OFF position. In
the ON position, the database cannot be modified. Thus, placing the switch in the ON position
eliminates the potential for remote database modification. If remote data entry is not desired, after
all installation and database entries are complete place the switch in the ON position.
When new gateway Modules and/or terminals are connected to a LAN, they will automatically
attempt to register with an LIK-MFIM50A. With the Registration switch (switch 3) in the ON
position, the system will recognize and respond to the registration request. With the switch in the
OFF position, the system will not respond to the request. During initial installation, the switch
should be placed in the ON position to permit the system to recognize and respond to registration
requests. If it is desired to deny future registrations, the switch should be placed in the OFF
position. This is useful when multiple systems may be connected to the same LAN. For details on
gateway Module and terminal registration, refer to the iPECS Admin & Program Manual.
The system database is initialized based on switch position 4. In the ON position, the system will
load default values in the system database when power is applied to LIK-MFIM50A or the Reset
button is pressed. Note if the system looses power for any reason with the switch in the ON
position, the database will be initialized. Place the switch in the ON position then, after completing
the system wiring and prior to any database entries, place the switch in the OFF position. For a
description of the initialization process, refer to the iPECS Admin & Program Manual.