12
ATTENTION: the an-frost protecons cannot intervene in the absence of electricity. If you an-
cipate this possibility, we recommend you add a good brand of an-freeze to the heang sys-
tem, following the producers instrucons.


When the power comes back on, the boiler will check the temperature measured by the two
probes and, if it suspects freezing veried by a parcular automac control cycle, alarm 39 will
be triggered. For more details, see the relave descripon in the paragraph "Alarms - boiler
block" on page 30.
We recommend that you completely empty the hot and cold sanitary water system, including
the sanitary circuit and the boilers sanitary exchanger. The an-frost funcon does not protect
the sanitary circuit outside the boiler.
Ambient An-Frost” Funcon
Note: if you want to use the Ambient An-Frostfuncon that is oen available in common room
thermostats or chronothermostats, it is necessary to leave the boiler in Winter
mode and NOT
in stand-by.
The Ambient An-Frostfuncon does not protect the sanitary circuit outside the boiler and,
especially, in areas where the heang system doesn’t reach. For this reason, we recommend
that you empty the cold and hot sanitary water from the parts of the system that are at risk of
freezing.


Note for the translator/writer: Place in this paragraph all the recommendaons relevant to the compli-
ance with laws in the desnaon naon/country (if any). As an example (from Italian regulaon):
as this boiler has an heat output lower than 35 kW (about 30000 Kcal/h),
it is not required to install the appliance in a dedicated room, provided that the room complies with
the regulaon in force and that all installaon rules assuring a safe and regular gas boiler operaon,
are strictly respected.
 when
a boiler with air draught from the installaon room (B… appliance type) is installed. Venlaon
must be made and sized in compliance with Laws and Rules in force.
at the end of the installaon, the installer must:
explain the operaon of the boiler and its safety devices to the user;
give this user this booklet and the documentaon within his/her competence, duly lled in where
required.