 Besides, for an opmal boiler funconing, wa-
ter pressure should be more than 1 Bar. A lower pressure could make dicult to restore correctly the
pressure the heang system, and reduce the ow of hot water available from the boiler.
In case of higher pressure it is indispensable to install a PRESSURE REDUCER upstream the
boiler.
If the wa-
ter hardness is more than 25° fr its required to install a soener to bring the hardness below that value.
Besides, the presence of solid residuals or impuries in the water (for example in case of new systems)
could compromise the correct funconing of the boiler. For DHW producon systems, the regulaon in
force prescribes a safety lter to protect the systems.

Thanks to its anfreeze system, inner components could never reach a temperature lower than 5°C. This
system is acvated when the boiler is supplied by the electrical and gas lines, provided that the pressure
in the heang system is correct.
In case of boiler installaon in rooms where temperature can drop down to 0°, it is advisable
to ll the heang circuit with an anfreeze liquid specic for heang systems, propylenic glycol
based, following the instrucons of its manufacturer. Pay aenon to the correct product con-
centraon: adding those substances to the heang water in incorrect dose could lead to the
deformaon of the seals and cause unusual noises during operaon.
ITALTHERM S.r.l. will not be held responsible for consequent damages.



This type B boiler, with open chamber and natural draught, is not suitable for outdoor installa-
on, neither in a parally protected place.