39

This remote control is more than a simple room thermostat.
Thanks to this, it is possible to manage the boiler in all its set-
 like DHW and CH temperature adjustment, boiler reset in
case of boiler block, and of course it works as a room thermo-
stat both in manual and weekly program mode. Its powered by
the boiler (in safety low voltage), so .
Extract the Remote Control from its package. 
   

Nor the Remote Control neither the relevant cable coming
from the boiler must not, for any reason, be connected to

To avoid malfuncons due to electrical noise, the Remote
Control connecons, as well as all low-voltage connecons,
should be kept separated from power supply cables, e.g. by
enclosing it into separate raceways.
The maximum overall cable length shouldn't exceed 50 m.
 Cut o electricity from boiler;
 install the device as described in the paragraph 4 of the supplied instrucon booklet;
 link the Remote Control wirings to the "Room Thermostat - Remote Control" cable coming out of
the boiler, by means of a suitable bipolar terminal. See also "Electrical diagram" on page 37;
Note: The Remote Control link is not polarized.
 power supply the boiler; 
on Summer otherwise the
 and the boiler goes into alarm 31 described below;
 check the correct work of the device. The electronics should recognize it automacally.
  ; the boiler work is man-
aged by the Remote Control, including the OFF, Summer and Winter modes, and the technical

Signal Probable causes 
31
Communication
error between the
Remote Control (if
present) and the
boiler
Disconnect the electrical supply to the boiler for 30 seconds by op-
erang the suitable external bipolar switch, turn the boiler's Sum-
mer/Winter knob on Summer
, then power supply the boiler.
If the lockout persists or reappears, call the Service Centre. Under
these condions, the boiler works only in DHW.
For the Technician: Problems on the oponal Remote Control
connecon link (passing close to supply cables or other electromag-
nec eld sources; connecon failure; cable length over 50 meters).
CONTROLLO REMOTO
EASYREMOTE
MANUALE DI
ISTRUZIONI