33
Signal Probable causes
42
RED
YELLOW
System error
Anomaly of inner
boiler device(s)
Mains electrical
power supply out
of tolerance limits
Detect the fault or anomaly also referring to the technical literature
reserved to the service centres.
– –
(??)
The “Hot Water”
knob
is on a
posion reserved
to the techni-
cian:
or service .
Turn the knob back along the scale .
– –
(??)
RED
it has been started,
by mistake (moreo-
ver very improb-
able), a procedure
reserved to the
Technician
In order to avoid malfuncons, do the following as soon as possible:
f turn the knob
on the o/unlock posion;
f turn the "Hot Water" knob
along the scale ;
f turn the knob
on the normal working posion (Summer or
Winter
along the scale ).
Warnings for servicing
All servicing operaons and gas conversions MUST BE CARRIED OUT BY QUALIFIED TECHNI-
CIANS, in compliance with the norms and laws in force (see an indicave list on page 4). Moreo-
ver, MAINTENANCE operaons must be carried out in compliance with the manufacturer pre-
scripons and with the laws and rules presently in force, for the parts not menoned in this
handbook.
Normally, it will be necessary to
execute the following operaons:
f Remove any possible oxidizaon from burners and electrodes;
f Remove the scale from the exchangers;
f Check integrity and stability of the ceramic bre coverings in the combuson chamber and proceed
eventually to substuon;
f Check the boiler ignion, switching o and operaon;
f Check the water and gas connecons ghtness;
f Check the gas consumpon at the minimum and maximum output;
f Verify that safety devices are correctly working;
f Verify the correct funconing of control and adjusng devices;
f Verify the correct funconing and the integrity of the ue system and of the relevant terminals and
accessories
f In case of works or servicing of the structures placed near the above menoned ducts and /or de-
vices and their accessories, switch o the boiler;
f Do not leave any inammable tanks and/or substances in the installaon room;