32
Signal Probable causes
10
Insucient system
pressure
(loss of water pressure
switch triggered)
Restore the correct pressure as described in "Preliminary opera-
ons" on page 9 or (preferibly bu the Technician) in "Heang system
lling and pressuring" on page 16.
Remark: Consider that the pressure, in normal condions, should not decrease with the progress of the me. If
this happens, there is probably a loss in the heang system. Somemes the loss is so small that it doesn’t
leave evident signs, but with the progress of the me it can cause the decreasing of the pressure. Also the
opening of the manual venng taps of radiators (intenonal or unintenonal) makes the pressure decrease.
Check that this doesn’t happen.
22
Memory-stored
data not coherent.
User: Disconnect the electrical supply to the boiler by operang the
suitable external bipolar switch, then connect it again aer a few
minutes. If the lockout persists or reappears, call the Service Centre.
Redo all the boiler sengs ("Max heang power adjustment" on
page 24 and "Electronic sengs" on page 26) to update the data in the
main board memory.
Replace the main board (consequently, redo the "Max heang pow-
er adjustment" on page 24 and "Electronic sengs" on page 26).
31
This alarm is described in paragraph "Remote Control Kit" on page 39.
33-34
Cabling congura-
on error.
Refer to the electric diagram (page 37) and check the integrity of the
wirings, especially the eventual short cable jumpers between two
contacts of the same connector (on the cabling connecons to the
electronic board).
35
RED
YELLOW
Unexpected ame
the control elec-
tronic has detected
the ame on the
burner when this
one should be o
Wait for the boiler automac reset (5 minutes) or reset it manually
by turning the knob
on the unlock posion , waing the
red light to turn o, then bringing the knob in the previous posion.
If the lockout persists or reappears, call the Service Centre
Detect eventual malfunconing of the gas valve (that does not
stop fully the gas ow, so the burner remains ignited) or of the elec-
tronics, ame detecon secon (that detects the ame presence
even if it's absent).
39
Suspected freezing
Aer a power fail-
ure, the boiler de-
tected tempera-
tures at the Heang
and DHW probes
equal to, or less
than, 0°C when
power was restored
The display shows the alarm code 39 while the boiler inhibits the
ignion of the burner and acvates the circulator, forcing water to
circulate in the hydraulic circuits.
If, during this me, the temperatures measured by the probes rise
above +1°C, the alarm is reset and the boiler returns to the normal
operaon.
Otherwise, the alarm will persist and you should suspect that water
has frozen at one or more points of the hydraulic circuit of the boiler
and/or system (with possible damage to the frozen parts). If the
alarm persists, call a qualied technician.
Find/replace the parts damaged by the freezing.