Power Supply Function
End
State
Set the running state after the list program is run-
ning over.
Last After the List program finishes run-
ning, the output is kept as the set-
ting in the last step, and the
working mode remains as the set-
ting in the List file.
None: No trigger signal output.
Tout: There is a trigger signal
output.
Normal After the List program finishes run-
ning, the working mode and volt-
age/current output return to the
settings before the List running.
None: No trigger signal output.
Tout: There is a trigger signal
output.
OFF After the List program finishes run-
ning, the output of the instrument
is turned off.
None: No trigger signal output.
Tout: There is a trigger signal
output.
Save to
group
Save the edited List program.
Edit List Program
The following takes CC priority mode as an example to introduce the operation
of editing two test steps.
1. Press the composite keys [Shift]+[I-set] (Function) on the front panel to en-
ter the function menu.
2. Select 1. LIST: Off and press [Enter].
3. Rotate the knob to select Edit and press [Enter] to enter the editing
interface.
Copyright © Itech Electronic Co., Ltd.