25
Yellow Status LEDs – this indication has four modes to show current operating status of the system. 
SeeFigure3.3(b)foradescriptionofthediffer entstates.
State Description
Off Nocameraisassignedtothischannel
On Cameraandcommunicationsaregood
SlowBlink Nocommunicationwithcamera
FastBlink Communicationwithca mera,novideoforsystemtoprocess.
Figure3.3(b)
Base Station Connection – this 6 way connector is for connection of the ICC‐2W Module to the Base
Station. For field installation only 4 pins areused;VS,GND, SDIO+ and SDIO‐. The twocenter pins are
notused.
ACPowerConnection–theICC‐2WModule
requires 120vacor240vac.Ifpowerisnotavailableonthe
detectorrackbackplaneoronly240vacisavailablethenpowershouldbeconnectedhere.
Channel1&2CallLEDs–theseindicators,twoforeachcamera,shouldilluminatewhencallsarebeing
placed to the outputs of the
ICC‐2W Module. They represent open collector outputs triggered by the
detectionzonethatthechannelitisassociatedwith.
Channel1&2TestSwitches–thesetoggleswitcheshavethreepositions.Thedefaultpositionisinthe
centerandisthepositiontheyshouldbekeptinduringnormal
operation.Theswitchcanbepushedup
to place a momentary call (contact closure) on the output channel or can be pushed down to place a
constantcallon the outputchannel fortestingor troubleshootin gpurposes.Whentestingiscomplete
besuretorestoretheswitchtothecenter
positionfornormaloperation.
RS‐232 Port – this serial port is used to communicate with the system. It is connected to a PCforuse
withtheVersiCamWirelessSoftwareConsole.