Installing the 100W-R and 100WP-R ERT Modules
TDC-0951-005 100W-R and 100WP-R Datalogging ERT Module Installation Guide 33
Proprietary and Confidential
7. If you have not already done so, connect the register to the water meter and fully tighten the mounting
screw (1) as directed by Badger Meter.
Note Mount the register on the meter in one of four different positions with respect to the direction of
water flow (refer to the manufacturer's installation directions).
8. If the standard Torx screw is used (1), a wire seal is not necessary.
If the optional slotted and drilled RTR screw is used, install a wire seal through the drilled screw from (1)
to (2), or as specified by utility policy.