Chapter 2 Planning a CCU/Repeater Installation
• A high-gain vertically polarized remote antenna (8.15 dBi) mounted remotely in place
of the direct attached solution.
Warning Do not install an 8.15 dBi antenna directly on the CCU. Antenna
installation directly on the CCU will compromise mechanical integrity and will not
meet the compliance requirement for a loss of 2.2 dB.
You must properly ground remote antennas during installation. When a remote antenna is
used, a lightning arrestor is recommended.
Coaxial cable that is used to connect the remote 900 MHz antenna to the collector or
repeater must be properly grounded. For more information, see Lightning Arrestor on
page 12. All coaxial cable connections must be weather-proofed per industry standards,
unless otherwise specified. When the collector or repeater is ordered with a remote 900
MHz antenna kit, some associated mounting hardware is included. Coaxial cables for the
remote 900 MHz antennas are not included in the kit. The installer must provide these
cables. For coaxial cable specifications, see Coaxial Cable on page 14.
For more information, refer to the following sections:
• Antenna Specifications on page 60
• Remote 900 MHz Antenna Placement on page 10
• Grounding the Remote/External Antenna Systems on page 10
• Performing an Antenna Sweep Test on page 72
• Antenna Line Sweeps Procedure on page 81
• Grounding Specifications on page 93
Lightning Arrestor
Install a lightning arrestor (or surge protector) capable of withstanding multiple lightning
strikes when you are using a remote/external antenna. This helps protect the collector or
repeater in the event of a lightning strike.
The lightning arrestor is fitted between the coaxial antenna cable and the RF jumper cable
that connects to the collector or repeater module. It includes a bulkhead connector
interface that mounts to a ground plate with a washer and nut. The arrestor is also
furnished with a ground lug, if your installation does not have provisions for a ground
plate. The ground lug on the arrestor is designed for #2 AWG solid or stranded wire.
Caution The lightning arrestor must be connected to an earth-ground.
The ground lug is manufactured by AMP/Tyco Electronics (part number 320754) and is
designed for #2 AWG solid or stranded wire (0.257-inch to 0.335-inch diameter). The lug
must be properly crimped (never soldered) to the wire using SOLISTRAND tooling
designed for the lug. The following figure details a proper crimp.
12 TDC-0971-011 CCU 100 and Repeater 100 Installation Guide