Performing an Antenna Sweep Test
Test Gear: Current and proper calibration; be sure that calibration is turned on during
the test. A qualified operator of the test equipment must perform the test.
Note If the system does not perform to the previous test specifications, the reasons
for system failure and possible remedies must be identified before leaving the
installation site.
TDC-0971-011 CCU 100 and Repeater 100 Installation Guide 73