SL7000 User Guide
From FW v8.01c, and with the use of the 4
th
sensor, a new fraud event is registered.
Under current diversion, the meter cumulates every second in specific registers the following data:
Diverted imported current calculated as ArmsH (CurrentDiversionRegister) from the current diversion value
of secondary
Duration (in seconds)
Calibrations history
The meter records the following calibration event parameters:
number of calibrations (incremental)
last calibration date and time
Configurations history
The meter records the following configuration event parameters:
number of objects configured (incremental)
last configuration date
Watchdog activity
The meter detects watchdog events and records the following parameters:
number of watchdog events (incremental)
last watchdog event (with time stamp)
Firmware Upgrade
This history is updated at reception of a Firmware upgrade request. Data stored in history are the following:
5 last firmware upgrade information (Firmware version, status and date time of the activation)