Technical description
UFER cumulative rate register
The excess energy over the UFER interval shall be accumulated in a rate only when the rate is active
(current rate). Only one rate is active at the same time.
UFER cumulative rate registers is not resetted at the beginning of each billing period
UFER total register
This register indicates total excess energy during the current billing period.
UFER cumulative total register
This registers indicates total excess energy during all the meter working duration.
DMCR Max General rate register
These registers indicate maximum excess demand for each rate during the current billing period.
DMCR cumulative rate register
These registers indicate maximum excess demand for each rate during all the meter working duration.
DMCR Max General total register
This register indicates total maximum excess demand during the current billing period.
DMCR cumulative total register
This register indicates total maximum excess demand during all the meter working duration.
DMCR Instantaneous register
This register holds the calculated value of DMCR reached in the last UFER Interval.
UFER Instantaneous register
This register holds the calculated value of UFER reached in the last UFER Interval.
Active Energy Cumulative Instantaneous register
This register holds the sum of Active energy totalized inside a UFER Period.
Reactive Energy Cumulative Instantaneous register
This register holds the sum of UFER Reactive energy totalized inside a UFER Period.
Active Demand Cumulative Instantaneous register
This register holds the sum of aggregate energy totalized inside a UFER Period.