Disassemble the bearing frame
1. Remove these plugs from the bearing frame (228A).
oil-fill plug (113A)
oil-drain plug (408A)
sight-oiler plug (408J)
four oil mist/grease connection plugs (408H)
oil-cooler inlet and outlet plugs (408L and 408M) or oil cooler
2. For the MTi and LTi models, remove the bearing frame foot-to-frame bolts (370F) and the frame foot
(241).
319
408N
408A
241
370F
408N
408W
372T
113A
408W
408M
761B
Guidelines for i-ALERT
Condition Monitor disposal
Precautions
WARNING:
Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these
temperatures could result in death or serious injury.
Never dispose of the condition monitor in a fire. This could result in death or serious injury.
Guidelines
The battery contained in the condition monitor does not contain enough lithium to qualify as reactive
hazardous waste. Use these guidelines when disposing of the condition monitor.
The condition monitor is safe for disposal in the normal municipal waste stream.
Adhere to local laws when you dispose of the condition monitor.